24725 CD57 Antibody Monitoring

CD57 Antibody Monitoring
Test Code: CD57
Synonyms/Keywords
Flow Cytometry​, CD 57
Useful For
Changes in the CD57 subset may be useful to monitor the response to therapy in Lyme disease.​
Specimen Requirements
Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
No​ Whole Blood​ Sodium-heparin Green Top Tube (GTT)​ ​** EDTA 1.0 mL​ 1.0 mL​ 0.5 mL​
Collection Processing Instructions

If a CBC with differential has been performed within 4 hours of the collection for the CD57, please send a copy of the CBC with differential results along with the CD57 specimen. If a CBC with differential has not been performed in this time period, include an order for the CBC with differential. This requires a separate EDTA whole blood (LTT) and two unstained EDTA smears. Notify Flow Cytometry Lab (800-222-5835, ext. 16385) before sending the specimen.

Specimen must arrive in Flow Cytometry within 48 hours of collection. ​

** For EDTA specimens, please  call 800-222-5835, ext. 16385 to determine acceptability.

Specimen Stability Information
Specimen Type Temperature Time
Whole Blood​ Room temperature​ 72 hours​
Rejection Criteria
Fixed specimens
Specimens more than 72 hours old ​
Refrigerated or frozen​
**​Contact Flow Cytometry f​​or suitability prior to rejection of any specimens.** 

​​

Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Marshfield​ Monday through Friday 1 day​ Flow Cytometry​
Test Information

This test was developed and its performance characteristics determined by Marshfield Labs.  It has not been cleared or approved by the US Food and Drug Administration.  This test is used for clinical purposes.  It should not be regarded as investigational or for research.

Absolute counts for this test are based on the CBC results provided at the time of testing, including lymphocyte percentage.
Reference Range Information
Performing Location Reference Range
Marshfield​ Not applicable
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​88184 ​1 ​Flow Cytometry, first marker
​88185 ​2 ​Additional marker, each
Classification

This test was developed and its performance characteristics determined by Marshfield Labs.  It has not been cleared or approved by the US Food and Drug Administration.  This test is used for clinical purposes.  It should not be regarded as investigational or for research.

Synonyms/Keywords
Flow Cytometry​, CD 57
Ordering Applications
Ordering Application Description
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
No​ Whole Blood​ Sodium-heparin Green Top Tube (GTT)​ ​** EDTA 1.0 mL​ 1.0 mL​ 0.5 mL​
Collection Processing

If a CBC with differential has been performed within 4 hours of the collection for the CD57, please send a copy of the CBC with differential results along with the CD57 specimen. If a CBC with differential has not been performed in this time period, include an order for the CBC with differential. This requires a separate EDTA whole blood (LTT) and two unstained EDTA smears. Notify Flow Cytometry Lab (800-222-5835, ext. 16385) before sending the specimen.

Specimen must arrive in Flow Cytometry within 48 hours of collection. ​

** For EDTA specimens, please  call 800-222-5835, ext. 16385 to determine acceptability.

Specimen Stability Information
Specimen Type Temperature Time
Whole Blood​ Room temperature​ 72 hours​
Rejection Criteria
Fixed specimens
Specimens more than 72 hours old ​
Refrigerated or frozen​
**​Contact Flow Cytometry f​​or suitability prior to rejection of any specimens.** 

​​

Useful For
Changes in the CD57 subset may be useful to monitor the response to therapy in Lyme disease.​
Reference Range Information
Performing Location Reference Range
Marshfield​ Not applicable
For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Marshfield​ Monday through Friday 1 day​ Flow Cytometry​
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​88184 ​1 ​Flow Cytometry, first marker
​88185 ​2 ​Additional marker, each
Classification

This test was developed and its performance characteristics determined by Marshfield Labs.  It has not been cleared or approved by the US Food and Drug Administration.  This test is used for clinical purposes.  It should not be regarded as investigational or for research.

For most current information refer to the Marshfield Laboratory online reference manual.