Coagulation Panel 2
Test Code: VCOFIB
Synonyms/Keywords
Coag Panel, Coagulation Panel, Clottng Panel
Test Components

VPT - Prothrombin Time

VAPTT - Activated Partial Thromboplastin Time

VFIB - Fibrinogen, Quantitative

Species
Alpaca, Avian, Bovine, Canine, Camelid, Caprine, Equine, Feline, Ferret, Mouse, Other, Ovine, Porcine, Primate, Rabbit, Rat
Test Category
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Plasma Citrated Blue Top Tube (BTT) 1.0 mL 400 uL
Collection Processing Instructions

All blue top tubes must be filled to the capacity indicated on the tube for accurate analysis.

Centrifuge the Blue Top Tube and remove plasma. Transfer plasma to a clear plastic transfer tube, freeze within 1 hour of collection.

Label tube and smears with animal’s name.

Specimen Stability Information
Specimen Type Temperature Time
​Plasma ​Frozen ​6 months
Rejection Criteria
​Frozen Unspun Blue Top Tubes
​Clotted Blue Top Tubes
​Insuffciently Filled Draw Tube
​Specimen Contaminated with IV Fluids
 
Interference
The blood to anticoagulant ratio is critical for accurate test results. If an inadequate blood sample is taken, results will be falsely prolonged.
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
​Cleveland ​Monday through Saturday Less than 2 hours​​ Mechanical Clot Detection​/Stago STart4
​Madison ​Monday through Friday Less than 2 hours Mechanical Clot Detection​/Stago STart4
​Marshfield ​Monday through Saturday​ ​Less than 2 hours Mechanical Clot Detection​/Stago Compact Max
​Milwaukee ​Monday through Saturday​ ​Less than 2 hours Mechanical Clot Detection​/Stago STart4
Marshfield Center Laboratory Section
Reference Intervals
Synonyms/Keywords
Coag Panel, Coagulation Panel, Clottng Panel
Test Components

VPT - Prothrombin Time

VAPTT - Activated Partial Thromboplastin Time

VFIB - Fibrinogen, Quantitative

Species
Alpaca, Avian, Bovine, Canine, Camelid, Caprine, Equine, Feline, Ferret, Mouse, Other, Ovine, Porcine, Primate, Rabbit, Rat
Test Category
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Plasma Citrated Blue Top Tube (BTT) 1.0 mL 400 uL
Collection Processing Instructions

All blue top tubes must be filled to the capacity indicated on the tube for accurate analysis.

Centrifuge the Blue Top Tube and remove plasma. Transfer plasma to a clear plastic transfer tube, freeze within 1 hour of collection.

Label tube and smears with animal’s name.

Specimen Stability Information
Specimen Type Temperature Time
​Plasma ​Frozen ​6 months
Rejection Criteria
​Frozen Unspun Blue Top Tubes
​Clotted Blue Top Tubes
​Insuffciently Filled Draw Tube
​Specimen Contaminated with IV Fluids
 
Interference
The blood to anticoagulant ratio is critical for accurate test results. If an inadequate blood sample is taken, results will be falsely prolonged.
Reference Intervals
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
​Cleveland ​Monday through Saturday Less than 2 hours​​ Mechanical Clot Detection​/Stago STart4
​Madison ​Monday through Friday Less than 2 hours Mechanical Clot Detection​/Stago STart4
​Marshfield ​Monday through Saturday​ ​Less than 2 hours Mechanical Clot Detection​/Stago Compact Max
​Milwaukee ​Monday through Saturday​ ​Less than 2 hours Mechanical Clot Detection​/Stago STart4
Laboratory Section